8
Quick Start Guide
2. Angle adapter and slide spade lugs into terminals 2 and 3 on the left side, as
shown in the figure below. Ensure that the positive and negative polarity
indicators match on the adapter and the terminal block.
3. Lower right side of adapter into terminals 2 and 3 on the right side and center
the adapter.
4. Tighten all terminal screws to lock divider in place.
Step 2: Verify operation
Operation can be verified using one of three methods: Field Communicator, the
Smart Wireless Gateway’s integrated web interface, or via AMS
®
Wireless
Configurator.
Field Communicator
For HART communication, an 848T Wireless DD is required. For connecting with a
Field Communicator, refer to Figure 3 on page 4.
Smart Wireless Gateway
In the Gateway’s integrated web interface, navigate to the Explorer page. This
page shows whether the device has joined the network and if it is communicating
properly.
Note
It may take several minutes for the device to join the network.
Note
If the device joins the network and immediately has an alarm present, it is likely due to sensor
configuration. Check the sensor wiring (see “Rosemount 848T Terminal Diagram” on page 10) and
the sensor configuration (see 848T Fast Key Sequence for Field Communicator” on page 10).
Function Key sequence Menu items
Communications 3,3
Join Status, Communications Status, Join
Mode, Number of Advertisements Heard,
Number of Available Neighbors, Number
of Join Attempts