Rosemount 848T Manual do Utilizador Página 33

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 36
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 32
33
Rosemount 848T Family
November 2014
www.rosemount.com
Product Certifications
Approved Manufacturing Locations
Rosemount Inc. - Chanhassen, Minnesota, USA
Rosemount Temperature GmbH - Germany
Emerson Process Management Asia Pacific - Singapore
European Directive Information
A copy of the EC Declaration of Conformity can be found at the
end of the Quick Start Guide. The most recent revision of the EC
Declaration of Conformity can be found at
www.rosemount.com.
Ordinary Location Certification from
FM Approvals
As standard, the transmitter has been examined and tested to
determine that the design meets the basic electrical,
mechanical, and fire protection requirements by FM Approvals,
a nationally recognized test laboratory (NRTL) as accredited by
the Federal Occupational Safety and Health Administration
(OSHA).
North America
I5 FM Intrinsically Safe and Nonincendive
Certificate: 3016555
Standards: FM Class 3600:1998, FM Class 3610:2010,
FM Class 3810:2005, NEMA-250:1997,
ANSI/ISA-60079-0:2009,
ANSI/ISA-60079-11:2009, IE 60529:2004
Markings: IS CL I, DIV 1, GP A, B, C, D; IS CL I, Zone 0, AEx
ia IIC T4; NI CL I, DIV 2, GP A, B, C, D;
T4(-50 °C
T
a
+70 °C), when installed per
Rosemount drawing 00849-1000; Type 4X;
IP66
See Table 16 at the end of the Product Certifications
section for Entity Parameters.
N5 FM Nonincendive and Dust-Ignitionproof
Certificate: 3016555
Standards: FM Class 3600:1998, FM Class 3810:2005,
NEMA-250:1997, ANSI/ISA-60079-0:2009,
ANSI/ISA-60079-11:2009, IE 60529:2004
Markings: NI CL I, DIV 2, GP A, B, C, D;
T4(-50 °C
T
a
+70 °C); DIP CL II/III DIV 1, GP E,
F, G; T5(-50 °C
T
a
+85 °C); when installed per
Rosemount drawing 00849-1000; Type 4X;
IP66
See Table 16 at the end of the Product Certifications
section for Entity Parameters.
I6 CSA Intrinsically Safe and Division 2
Certificate: 1261865
Standards: CAN/CSA C22.2 No. 0-M91 (R2001), CSA Std.
C22.2 No. 25-1966, CSA Std. C22.2 No.
30-M1986, CAN/CSA C22.2 No. 94-M91, CSA
C22.2 No. 142-M1987, CAN/CSA C22.2 No.
157-92, CSA Std. C22.2 No. 213-M1987, CSA
Std. C22.2 No 60529:05;
Markings: Intrinsically Safe for CL I, DIV 1 GP A, B, C, D;
Suitable for CL I DIV 2 GP A, B, C, D; when
installed per Rosemount drawing 00849-1016;
T3C; Type 4X, IP66
N6 CSA Division 2
Certificate: 1261865
Standards: CAN/CSA C22.2 No. 0-M91 (R2001), CSA Std.
C22.2 No. 25-1966, CSA Std. C22.2 No.
30-M1986, CAN/CSA C22.2 No. 94-M91, CSA
C22.2 No. 142-M1987, CSA Std. C22.2 No.
213-M1987, CSA Std. C22.2 No 60529:05;
Markings: Suitable for CL I DIV 2 GP A, B, C, D when
installed per Rosemount drawing 00849-1016;
T3C; Type 4X, IP66
Europe
I1 ATEX Intrinsic Safety
Certificate: Baseefa09ATEX0022X
Standards: EN 60079-0:2012, EN 60079-11:2012;
Markings: II 1 G Ex ia IIC T4/T5 Ga,
T4(-60 °C
T
a
+70 °C), T5(-60 °C T
a
+40 °C);
See Table 16 at the end of the Product Certifications
section for Entity Parameters.
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than
1GΩ. To avoid electrostatic charge build-up, it must
not be rubbed or cleaned with solvents or a dry cloth.
2. The power module may be replaced in a hazardous
area. The power module has surface resistivity greater
than 1GΩ and must be properly installed in the
wireless device enclosure. Care must be taken during
transportation to and from the point of installation to
prevent electrostatic charge build-up.
3. The enclosure may be med from aluminum allow with
a protective polyurethane paint finish; however, care
should be taken to protect it from impact or abrasion
when located in Zone 0.
Technical Regulations Customs Union (EAC)
IM Contact an Emerson Process Management representative
for additional information.
Vista de página 32
1 2 ... 28 29 30 31 32 33 34 35 36

Comentários a estes Manuais

Sem comentários