14
Reference Manual
00809-0100-4697, Rev GA
Section 2: Installation
November 2014
Installation
2.5 Switches
Figure 2-9. Switch Location on the Rosemount 848T
Security
After configuring the transmitter, the data can be protected from unwarranted changes. Each
848T is equipped with a security switch that can be positioned “ON” to prevent the accidental
or deliberate change of configuration data. This switch is located on the front side of the
electronics module and is labeled SECURITY.
See Figure 2-9 for switch location on the transmitter label.
Simulate enable
The switch labeled SIMULATE ENABLE is used in conjunction with the Analog Input (AI) and
Multiple Analog Input (MAI) function blocks. This switch is used to simulate temperature
measurement.
Not used
The switch is not functional.
2.6 Tagging
Commissioning tag
The 848T has been supplied with a removable commissioning tag that contains both the Device
ID (the unique code that identifies a particular device in the absence of a device tag) and a space
to record the device tag [the operational identification for the device as defined by the Piping
and Instrumentation Diagram (P&ID)].
When commissioning more than one device on a fieldbus segment, it can be difficult to identify
which device is at a particular location. The removable tag, provided with the transmitter, can
aid in this process by linking the Device ID to its physical location. The installer should note the
physical location of the transmitter on both the upper and lower location of the commissioning
tag. The bottom portion should be torn off for each device on the segment and used for
commissioning the segment in the control system.
NOT USED